Degree-day values can be calculated using climatic data. Thus, seasonal, monthly, daily and hourly energy requirements for heating and cooling in buildings can be calculated. The effect of outside ambient temperature can be determined by means of the degree-day method in determining the basic temperature values in buildings. The altitude and latitude affect significantly the temperature distribution in the Earth. Thus, the latitude and altitude values are required to determine the degree hour values.This study was taken in 9 provinces located in the Southeastern Anatolia Region (SAR). The annual outdoor dry-bulb thermometer temperatures for a long period of nine provinces in the SAR were obtained to determine heating and cooling degree hour values according to the six different base temperatures. According to the suggested six different base temperature values, the cumulative long-term annual heating degree-hour (HDH) value was 50862 in total for Gaziantep province. The lowest cumulative long-term annual heating degree-hour value took place in Sanliurfa province as 39638. Also, the highest total cooling degree-hour (CDH) value took place in Sanliurfa province as 10886 degree-hour value and the lowest value took place in Sirnak province as 3909.It was determined that there was not an exact linear or monotonous relationship between ...
Information on the energy needs of agricultural production activities carried out in any region can be obtained in advance. Many methods are used for this purpose. One of them is a degree-hour method. Kumluca district of Antalya province where pepper cultivation is done intensively was chosen as a study area. The growers prefer autumn production of pepper plants inside the greenhouses in this region. Production starts in early October and last until June. The long-term (1960 - 2015) thermometer temperatures in the study area were obtained from the Turkish State Meteorological Service. In this study, by using only meteorological data, during each growing season (planting, flowering, pollination, fruit ripening and harvesting) were obtained degree-hour values for the pepper plant and evaluated with Student-t test. Regression coefficients were obtained by correlating heating and cooling degree-hour values with different temperature values which are recommended during the vegetative growing season for the pepper plant. Regression analysis was performed between obtaining heating and cooling degree-hour values (dependent variable) and annual mean heating and cooling degree hour values (independent variable) which are suggested basic temperature values. In conclusion, the regression coefficients were determined as 0.99 for out of greenhouse heating degree-hour and as 0.90-0.99 for ...
In this study, the heating and cooling conditions of the greenhouses in Antalya were examined and suggestions were made for solutions of the problems that emerged. The Simple Random Sampling Method was used in determining the number of enterprises to be surveyed. The number of enterprises to be surveyed was determined as 246 with a 90 % confidence limit and 10 % error rate. It was determined that the greenhouses enterprises surveyed were heating at 96.34%. It has been determined that the most commonly preferred type of heater in the region is the stove and that the stove is heated only to protect the product from frost damage. In accordance with the data obtained from the research area, it was determined that one stove was used for 1000 m2 greenhouse floor area. It has been determined that 92.68% of the surveyed greenhouse enterprises are trying to reduce the excess temperature inside greenhouse by natural ventilation. It was determined that both the sidewall and roof ventilation were made at 45.93% of the greenhouse enterprises where examined in the research area. It has been determined that the ratio of ventilation area to greenhouse floor area changes between 10 and 15 in 32.52% ...
In this study, it is aimed to determine the effect of greenhouse cover material of different color on the number of heating (HDHN) and cooling degree hours (CDHN) and heating (HDH) and cooling degree hours (CDH) of the lettuce plant. For this purpose, the study was carried out in the CtrlG (Control transparent PE greenhouse), RedG (Red PE greenhouse) and BlueG (Blue PE greenhouse). The study was completed in 2018 at ISUBU research and application farm. The temperature values measured in the three greenhouses with the same dimensions were the material of the study. HDH, CDH, HDHNs, and CDHNs were calculated by examining the measured temperature values and suggested temperature values for the lettuce plant. By using these values, it was tried to determine suitable cover material during the growing period of the lettuce plant. It has been concluded that the use of colored covering material is more suitable in terms of energy needs in almost all growing periods of lettuce plants. By comparing the values calculated for RedG and BlueG based on CtrlG, the coefficients of variation were calculated to determine which data series or series were more similar to each other. According to the coefficients of variation, the ...